SmartView-Ethernet-Extenders-2100-SVE
Rath Janus

SmartView Ethernet Extenders 2100-SVE

Only available in
USA
COMPLIANT WITH
ASME-and-CSA-logo
ASME /CSA
IBC-and-ICC-logo
IBC/ICC
Overview
The 2100-SVE SmartView Ethernet Extenders supplies an extra 1A to the SmartView Controller. It extends over 1-pair of wiring.
Play
SmartView Two-Way Elevator Visual Communication System
2100-SVE-diagram

Dimensions: 1″ H x 3.7″ W x 2.75″ D

Power Requirements:

  • Injector Power:56V-65W power adapter with dc jack included (120vac power cord). Requires backed up 120v source or RATH RP7700104S
  • Extender Power: Supplies 1A to the SmartView Controller

Wiring Requirements:
Extender Wiring:

  • Extends up to 1,640 feet over single pair of wiring between extenders (requires single pair, 18-24ga, shielded or unshielded)
  • CAT5E with RJ45 connectors required from network switch and the SmartView Controller to each extender
  • Main Unit (Injector) has LAN In (internet connection) and LRP Out (two wire connection)
  • Remote Unit (Extender) has LRP In (two wire connection from main unit) and PoE Out (Ethernet connection to SmartView Controller)

Additional Features:

  • Included RJ45 adapters for Interlink Cabling
  • Supplies power and communication to the SmartView Controller

Specifications:

  • Environmental: -49°F to 168°F (-45°C to 76°C)
  • Mounting: Behind the Panel

Warranty: 2 years