Find your region

Avire-Logo-Group

For countries not listed, see the Global site.

Note: Some products are available only in certain regions. Contact us regarding local availability.

EMS5-Call-Director-System

EMS5 System Call Director for 1-8 Elevator Phones

Only available in
USA
COMPLIANT WITH
ASME-and-CSA-logo
ASME /CSA
Overview
The EMS5 system by Janus is designed to provide seamless two-way, person-to-person voice communication for elevators, accommodating up to 8 elevator phones on a stand-alone unit, or up to 24 on three daisy-chained units. Ideal for small to medium installations, this system offers flexible communication options. With add-on lobby or machine room master phones, the EMS5 ensures all rescue locations have voice pathways to get the passenger the assistance it needs.
  • Small, Compact Size: Compact but powerful footprint allows for an EMS5 to be installed to be installed on any wall, even if construction is completed, making it an effective solution for retrofit installations.
  • Stand-Alone Capability: The EMS5 provides person-to-person voice off-site communication capabilities utilizing only one dedicated phone line. For installations with 24-7 on-site monitoring, the EMS5 can also be set up as a stand-alone intercom system, the site to meet code without reoccurring costs in un-necessary phone lines.
  • All components are engineered to meet current industry codes, ensuring reliability and peace of mind
EMS5-Call-Director
EMS 5 Call Director
Dimensions: 8-3/8″ W x 14-1/8″ H x 2-5/16″ H

Code Compliance:
• FCC Registered
• CSA Listed

Power:
• 110vac to 16vac @ 1A power transformer supplied
• Loop Current Range: 10mA to 60mA (20mA typical)

Additional Features:
• Allows onsite communication between Master Station and all other devices
• Four-hour battery backup
• Saves phone line expenses
• Functions as a stand alone intercom system
• Phone line monitoring available
• Onboard keypad
• Low battery alarm call
• Built in three number dialer
• Extended voice chip capability
• On or offsite monitoring capabilities
• Fully programmable voice chip
• Onsite diagnostic read out

Weight: 9 lbs.

Warranty: 2 years
Order-Online-Button

SHW-Lobby-Master-StationSHW Lobby Master Station

Dimensions: 9-3/16″ W x 9-3/16″ H x 5″ D

• The SHW Master Station Phone provides two way communication between the lobby or fire control room and the elevator phones on an EMS5 System.
• Once a call is placed from an elevator phone, the call will be directed to the SHW phone. The digital display will show the number of the elevator calling.

Power: 110vac to 12vdc @ 500mA power transformer supplied

Additional Features:
• A master station combined with the EMS5 system can operate without a phone line where 24-hour on-site monitoring is used
• Allows onsite communication between master station and all other devices connected to the EMS5
• Multiple master stations can be used on a system
• Wall mount, flush mount, desk set, and hands-free options available

Weight: 6 lbs.

Warranty: 2 years
Order-Online-Button
SHW-MR-Lobby-Master-Station
SHW-MR Machine Room Master Station

Dimensions: 9-3/16″ W x 9-3/16″ H x 5″ D

• The SHW-MR Master Station Phone provides two way communication between the machine room or fire control room and the elevator phones on an EMS5 System.
• Once a call is placed from an elevator phone, the call will be directed to the SHW-MR phone. The digital display will show the number of the elevator calling.

Power: 110vac to 12vdc @ 500mA power transformer supplied

Additional Features:
• Allows onsite communication between the machine room and all other devices connected to the EMS5
• Multiple Machine Room masters can be used on a system
• Digital display shows origin of call
• Wall mount, flush mount, desk set, and hands-free options available

Weight: 6 lbs.

Warranty: 2 years
Order-Online-Button

Files and Resources

EMS5_Call Director Data Sheet
Datasheets
Download
EMS5_Call Director Specifications
Specifications
Download
EMS5_Master Stations Manual
Install Guides
Download
SHW_Machine Room Master Station Data Sheet
Datasheets
Download
SHW-MRI-1_Machine Room Intercom Data Sheet
Datasheets
Download
SHW-MRI-2_Machine Room Intercom Data Sheet
Datasheets
Download
SHW Consultant Specifications
Specifications
Download
EMS5_Call Director Data Sheet
Datasheets
Download
EMS5_Call Director Specifications
Specifications
Download
EMS5_Master Stations Manual
Install Guides
Download
SHW Consultant Specifications
Specifications
Download

Specifiers' Corner

The Specifiers’ Corner is designed to provide Architects, Engineers, Contractors, Fire Marshals, Building Code Officials, Inspectors, AHJs, and end users with the essential information that may be needed for a project: Submittal Documents, Manuals/Wiring Diagrams, Data Sheets,CAD and Code Requirements

Contact info

You also can contact us through our phone number, our email address, and we’ll get back to you

rath-janus@avire-global.com
+800-451-1460
Office Locations

Education, Training and Support

We believe that ongoing education is paramount to your professional development.

As the code and training experts, our website offers all the documentation and educational resources needed to assist you in making the right decisions.