2 Hour Fire-Rated Cable Series

Compliant with
Overview
RATH® 2-Hour Fire Rated Cable is designed to maintain circuit integrity during fire conditions, providing critical protection for life safety communication systems.

Engineered for two-way communication and emergency response systems, this cable complies with stringent UL standards and is ideal for high-rise buildings and areas of refuge that require survivability in extreme heat and flame.

Product Variants

Part NumberRP66010001RP66010002661026612066125RP6600100MRP6600300MRP6600100M4RP6600300M4
Image
Data SheetDatasheet_18-12AWG-CIC_2-Hour Fire-Rated Circuit Integrity Cable.pdfDatasheet_18-12AWG-CIC_2-Hour Fire-Rated Circuit Integrity Cable.pdfDatasheet_18-4AWG-CIC_2-Hour Fire-Rated Circuit Integrity CableDatasheet_18-4AWG-CIC_2-Hour Fire-Rated Circuit Integrity CableDatasheet_18-8AWG-CIC_2-Hour Fire-Rated Circuit Integrity CableDatasheet_22-4AWG-CIC__2-Hour Fire-Rated Circuit Integrity CableDatasheet_22-4AWG-CIC__2-Hour Fire-Rated Circuit Integrity CableDatasheet_22-8AWG-CIC2-Hour Fire-Rated Circuit Integrity CableDatasheet_22-8AWG-CIC2-Hour Fire-Rated Circuit Integrity Cable
Conductor18-12 AWG Solid Bare Copper18-12 AWG Solid Bare Copper18-4 AWG Solid Bare Copper18-4 AWG Solid Bare Copper 18-8 AWG Solid Bare Copper22-4 AWG Solid Bare Copper 22-4 AWG Solid Bare Copper 22-8 AWG Solid Bare Copper22-8 AWG Solid Bare Copper
Length500 ft.1,000 ft.500 ft.1,000 ft.500 ft.328 ft. 984 ft.328 ft.984 ft.
Weight24.5 lbs (49 lbs/kft)49 lbs (49 lbs/kft)47.5 lbs (95lbs/kft95 lbs (95 lbs/kft)63 lbs (126 lbs/kft)19 lbs (58.22 lb/kft)57 lbs (58.22 lb/kft)31 lbs (95 lb/kft)94 lbs (95 lb/kft)
Nominal Diameter0.309″0.309″0.465″0.465″0.504″0.322″0.322″0.397″0.397″
Temperature221ºF (105ºC)221ºF (105ºC)194ºF (90ºC)194ºF (90ºC) 194ºF (90ºC) Operation: -4°F to 140°F (-20°C to 60°C)
Installation: 32°F to 284°F (0°C to 50°C)
Operation: -4°F to 140°F (-20°C to 60°C)
Installation: 32°F to 284°F (0°C to 50°C)
Operation: -4°F to 140°F (-20°C to 60°C)
Installation: 32°F to 284°F (0°C to 50°C)
Operation: -4°F to 140°F (-20°C to 60°C)
Installation: 32°F to 284°F (0°C to 50°C)

Files and Resources

Datasheet_18-12AWG CIC 2-Hour Fire-Rated
Data Sheets
Download
Datasheet_18-8AWG CIC 2-Hour Fire-Rated
Data Sheets
Download
Datasheet_18-4AWG-CIC 2-Hour Fire-Rated
Data Sheets
Download
Datasheet_22-8AWG CIC 2-Hour Fire-Rated
Data Sheets
Download
Datasheet_22-4AWG CIC 2-Hour Fire-Rated
Data Sheets
Download
2 Hour Fire-Rated Cable RP8500001 Installation Manual
Install Guides
Download
Area of Refuge Signage Specifications
Specifications
Download
Area of Rescue Signage Specifications
Specifications
Download

Education, Training & Support

We believe that ongoing education is paramount to your professional development.


As the code and training experts, our website offers all the documentation and educational resources needed to assist you in making the right decisions.

Education

Whether you’re looking to build your knowledge, troubleshoot an issue, or connect with a product expert – were here to help! Access the tools and support you need to make informed, code-compliant decisions.

See Education

FAQs

Get quick answers to common questions.

See FAQs

Technical Support

Schedule time with a support specialist.

Technical Support

Contact Sales

Speak with a sales expert about your project needs.

Contact Sales