COMPLIANT WITH
NFPA 72®
IBC-and-ICC-logo
IBC/ICC
Overview
A code-compliant Area of Refuge System requires a central control point to manage emergency assistance calls from Call Boxes.
  • The IP Command Center base stations, designed to handle up to 128 Call Boxes, provide a seamless means of communication between stranded individuals, rescue personnel, and offsite parties
  • Utilizing Voice Over Internet Protocol (VOIP), this system offers clear and efficient communication over a network or internet connection
  • Versatile solution that can be installed in new construction, retrofit projects, or when the building owner has upgraded their phone system to IP
  • The system includes Base Stations & Distribution Modules, with Power Supply and battery backup sold separately, providing a complete and robust solution for your Area of Refuge needs
  • This IP solution is ideal for single or multiple phone installations requiring internal communication with the Area of Refuge Call Boxes, ensuring safety and compliance without compromise

Power Requirements:

  • Command Center and Sub-Master Stations are powered from PoE

Wiring Requirements:

  • Command Center to Distribution Module: Single pair or via IP (contact RATH® for a quote on the IP version)

Phone Capabilities:

  • Calls wait in queue until previous call is disconnected and receive a message stating that an emergency call is in progress. When the prior call clears, the next phone in queue is connected
  • Calls wait in queue until previous call is disconnected and receive a message stating that an emergency call is in progress. When the prior call clears, the next phone in queue is connected
  • Includes handset and speaker phone for communication to Call Boxes
  • Works with our model 2100 series IP Call Boxes. Connect back to Distribution Module via an Ethernet connection. Max 300’ between network switches. IP Call Boxes require PoE at 802.3af
  • LEDs indicate which Call Boxes have initiated a call
  • Rescue personnel can communicate with individual Call Boxes and outside party
  • Audible alert sounds when Call Boxes place a call until Command Center joins conversation

Distribution Module Features:

  • Included with Command Center
  • Surface mount
  • Install on a wall or table top
  • Requires 120vac power with battery backup or RATH Power Supply with battery backup
  • Single dedicated phone line or as an Intercom System

Additional Features:

  • Can be configured with the main Command Center and multiple Sub-Master Stations (available in desk, surface, or flush mount)

Specifications:

  • Design: Powder coated steel enclosure with twist lock closure
  • Mounting: Surface, flush, or desk mount

Warranty: 2 years


Choose from Surface, Flush or Desk Mount

Available in 10, 16, 32, 48, 64, 80, 96, 112 or 128 Zone


2500-__RC-RCF-Series-Surface-Flush Mount Command Center
2500-__RCV Series Surface Mount
2500-__RCV Flush Mount


Surface Mount
Zone: 10 (2500-10RCV) 16 (-16RCV) 32 (-32RCV) 48 (-48RCV)
64 (-64XRCV) 80 (-80XRCV) 96 (-96XRCV) 112 (-112XRCV) 128 (-128XRCV)

2500-10RCV, 16RCV = 15.14″ H x 12″ W x 6.19″ D
2500-32RCV, 48RCV, 64XRCV, 80XRCV, 96XRCV,
112XRCV, 128XRCV = 21.03″ H x 20.3″ W x 5.19″ D

Flush Mount
Zone: 10 (2500-10RCFV) 16 (-16RCFV) 32 (-32RCFV) 48 (-48RCFV)
64 (-64XRCFV) 80 (-80XRCFV) 96 (-96XRCFV) 112 (-112XRCFV) 128 (-128XRCFV)

2500-10RCFV, 16RCFV
Front Frame: 16.06″ H x 14″ W x 3.07″ D
Back Box: 15.64″ H x 12″ W x 3″ D

2500-32RCFV, 48RCFV, 64XRCFV,
80XRCFV, 96XRCFV, 112XRCFV, 128XRCFV
Front Frame: 21.13″ H x 25″ W x 3.06″ D
Back Box: 20.66″ H x 23″ W x 3″ D

2500-__NC-Series-Desk-Mount
2500-__NC Series Desk Mount
See data sheet for dimensions

Zone: 10 (2500-10NCV)
16 (-16NCV)
32 (-32NCV)
48 (-48NCV)
64 (-64XNCV)
80 (-80XNCV)
96 (-96XNCV)
112 (-112XNCV)
128 (-128XNCV)











Command-Center-Distribution-Modules

Distribution Modules
10-48 Zone System = 2.04″ H x 17.28″ W x 11.8″ D
64-128 Zone System = 6.83″ H x 17.18″ W x 8.9″ D

















Files and Resources

2100-LTEGSM4-2_Cellular Gateway AT&T Data Sheet
Datasheets
Download
Area of Refuge Mounting Guide
Install Guides
Download
Area of Rescue Signage Specifications
Specifications
Download
Elevator Landing Signage Specifications
Specifications
Download
RP8500PBXVOIPG_VoIP Command Center Installation Manual
Install Guides
Download
2500-10NCV-128NCV_IP CommandCenter Desk Mount-CAD Drawing
Specifications
Download
2500-10RCFV_IP CommandCenter Flush Mount-CAD Drawing
Specifications
Download
2500-16RCFV-128RCFV_IP CommandCenter Flush Mount-CAD Drawing
Specifications
Download
2500-10RCV_IP CommandCenter Surface Mount-CAD Drawing
Specifications
Download
2500-16RCV-128RCV_IP CommandCenter Surface Mount-CAD Drawing
Specifications
Download
2500-10-48 Zone_IP CommandCenter Distribution Module-CAD Drawing
Specifications
Download
2500-64-128 Zone_IP CommandCenter Distribution Module-CAD Drawing
Specifications
Download
IP CommandCenter Block Diagram-CAD Drawing
Specifications
Download
IP CommandCenter with IP Call Boxes Block Diagram-CAD Drawing
Specifications
Download
IP CommandCenter with Analog Call Boxes Block Diagram-CAD Drawing
Specifications
Download

Specifiers’ Corner

The Specifiers’ Corner is designed to provide Architects, Engineers, Contractors, Fire Marshals, Building Code Officials, Inspectors, AHJs, and end users with the essential information that may be needed for a project: Submittal Documents, Manuals/Wiring Diagrams, Data Sheets,CAD and Code Requirements

Contact info

You also can contact us through our phone number, our email address, and we’ll get back to you

rath-janus@avire-global.com
+800-451-1460
Office Locations

Education, Training and Support

We believe that ongoing education is paramount to your professional development.

As the code and training experts, our website offers all the documentation and educational resources needed to assist you in making the right decisions.