{"id":9842,"date":"2025-04-23T09:03:48","date_gmt":"2025-04-23T14:03:48","guid":{"rendered":"https:\/\/www.avire-global.com\/en-us\/?post_type=division&p=9842"},"modified":"2025-10-27T01:56:27","modified_gmt":"2025-10-27T06:56:27","slug":"public-safety-distributed-antenna-systems-erces-errcs","status":"publish","type":"division","link":"https:\/\/www.avire-global.com\/en-us\/divisions\/life-safety\/public-safety-distributed-antenna-systems-erces-errcs\/","title":{"rendered":"Public Safety Distributed Antenna Systems (ERCES\/ERRCS)"},"content":{"rendered":"
\n\t
\n\t\t\"\"\t<\/div>\n<\/div>\n\n\n\n
\n\t\t\t
\n\t\t
\n\t\t\t
\n\t\t\t\t
\"Rath\"<\/div>\n\t\t\t\t

Public Safety Distributed Antenna Systems (ERCES\/ERRCS)<\/h1>\n\t\t\t\t
\n\t\t\t\t\t\n\n

Public Safety Distributed Antenna Systems (DAS) are designed to amplify radio signal coverage and improve emergency responder communication\u00a0<\/strong>within buildings, especially in areas where traditional radio signals may be obstructed or weakened. These systems are critical for maintaining reliable communication for emergency personnel during critical incidents.<\/p>\n\n\n\n

RATH\u00ae Public Safety DAS solutions<\/strong>\u00a0ensure optimal radio signal coverage, improving safety for both occupants and responders by providing clear, uninterrupted communication. Our systems are specifically designed to optimize signal quality and simplify installation, combining multiple frequency bands and\/or battery backup units into single cabinets. The unique card-based system offers the ultimate building flexibility.\u00a0<\/p>\n\n\n\n

RATH\u00ae Public Safety DAS systems<\/strong>\u00a0comply with NFPA 1221\/1225, NFPA 72, UL 2524, FCC requirements and local fire and safety codes, ensuring they meet stringent standards for emergency communication systems and provide critical coverage in case of emergencies.<\/p>\n\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\tCompare the systems<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t

\n\t\t\t\t\"firefighter\t\t\t<\/div>\n\t\t<\/div>\n\t<\/div>\n\t<\/div>\n\n\n
\n\t
\n\t
\n\t\t

Solutions<\/h2>\n\t\t\t<\/div>\n\t
\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t
\"\"<\/div>\n\t\t\t\t\t\t
\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t
Fiber DAS<\/div>\n\t\t\t\t\t\t\t\t
The RATH\u00ae Fiber Public Safety DAS ensures high-performance signal distribution for critical communication needs in large buildings and campuses, capable of covering various combinations of 700, 800, UHF, VHF and FirstNet in a single system. \n\nFiber-optic technology ensures minimal signal loss over long distances. The advanced filtering technology ensures that communication over any and all public safety bands are transmitted with clarity and reliability, making this a go-to solution for large buildings requiring robust, uninterrupted communication.\n\nThe RATH\u00ae Fiber Public Safety DAS is designed for scalability and is field-upgradable.<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tNFPA 1221\/1225<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tUL 2524<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tFCC<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\tSee product<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t
\"passive<\/div>\n\t\t\t\t\t\t
\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t
Passive DAS BDA<\/div>\n\t\t\t\t\t\t\t\t
The RATH\u00ae Passive Public Safety DAS offers a cost-effective and space-saving solution for any building that needs to support multiple public safety frequency bands for various emergency response services. Combinations of 700, 800, UHF, VHF and FirstNet can be configured in just a single cabinet. \n\nAdvanced filtering technology delivers strong, clear signals, even in challenging environments, offering an excellent balance of performance and cost-effectiveness for less demanding applications.\n\nThe system is designed for scalability and is field-upgradable.<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tUL 2524<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tNFPA 1221\/1225<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tFCC<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\tSee product<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t
\"\"<\/div>\n\t\t\t\t\t\t
\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t
Passive DAS BDA + Integrated Battery Backup<\/div>\n\t\t\t\t\t\t\t\t
The SAFE-1050 is the first-ever system to include a BDA and an integrated battery backup unit in a single cabinet, creating the most compact and efficient public service DAS solution on the market.\n\nAVAILABLE FOR ORDER STARTING SEPTEMBER 1, 2025!\n \nUsing the signature Safe-Com plug-in card system, the innovative SAFE-1050 supports single band configurations of 700 or 800 bands and dual-band (700\/800) configurations. \n\nThe unit’s proprietary super-heterodyne front end, along with digital Class A filtering, significantly improves the system’s ability to handle strong and weak signals simultaneously (near-far performance) and handles interlaced frequencies with ease. \n\nThe unit uses a state-of-the-art, lightweight lithium iron phosphate (LiFePO4) battery pack, complete with cell balancing technology and built-in monitoring to prevent overcharge and over-discharge, all designed to extend the life of the battery. \n\nThis all-in-one system was designed to require the least amount of time, effort and physical space to install. The system can be expanded or modified with ease over time.\n\nUL2524 certified, meets NFPA 1221\/1225 | FCC ID: 2AKSM-SAFE5\n\n* Pair with the Safe-Com remote annunciator.<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tUL 2524<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tNFPA 1221\/1225<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tFCC<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\tSee product<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t
\"\"<\/div>\n\t\t\t\t\t\t
\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t
Battery Backup Unit<\/div>\n\t\t\t\t\t\t\t\t
The Safe-Com battery backup unit features our state-of-the-art Lithium Iron Phosphate (LiFePO4) battery technology, designed to enhance performance and be lighter in weight and more compact than traditional batteries.\n\nThe battery system monitors and prevents both overcharge and over-discharge of the batteries, with overcurrent protection and cell-balancing circuitry to extend the life of the batteries. In the case of an outage, the integrated AC power supply offers a smooth transition from AC power to battery power.\n\nThe new battery technology is less likely to overheat versus legacy battery options, and this innovative design features no outgassing, low self-discharge, and no memory effect. These batteries are also more environmentally friendly than traditional alternatives as they do not contain cobalt or other toxic chemicals found in lead-acid or lithium-ion batteries.\n\nUL2524 certified, meets NFPA 1221\/1225<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tUL 2524<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tNFPA 1221\/1225<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\tSee product<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t
\"\"<\/div>\n\t\t\t\t\t\t
\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t
Remote Annunciator<\/div>\n\t\t\t\t\t\t\t\t
The Safe-Com remote annunciator features LED and audible alerts for code-required alarms with additional form-C relays for external connections. A single CAT5 cable is provided to deliver power from the BDA.\n\nLEDs are tested using a magnet\/magnetic switch that cycles the LEDs through their colors with a quick tap. Users can temporarily mute the audible alarms for 24 hours during install, testing or maintenance by holding the magnet over the magnetic switch for 5 seconds. This does not prevent new alarms from sounding.\n\nMeets NFPA 1221\/1225 requirements<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tNFPA 1221\/1225<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tUL 2524<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t
\n\t\t\t\t\t\t\t\t\tSee product<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n<\/div>\n<\/div>\n\n\n\n
\n

Compare Systems at a Glance<\/h2>\n\n\n\n
Features<\/th>Fiber DAS Systems<\/a><\/th>Passive DAS Systems<\/a><\/th><\/tr><\/thead>
Ideal Use Case<\/strong><\/td>Large buildings, high-rises, multi-building campuses<\/td>Mid-sized to small buildings with straightforward layouts<\/td><\/tr>
Signal Distribution<\/strong><\/td>Fiber optic cable<\/td>Coaxial cable<\/td><\/tr>
Coverage Range<\/strong><\/td>Long-distance signal transmission with minimal loss<\/td>Shorter distances; more dependent on building layout<\/td><\/tr>
Scalability<\/strong><\/td>Highly scalable across multiple floors or structures<\/td>Less scalable; best for simpler, compact environments<\/td><\/tr>
Installation Complexity<\/strong><\/td>More complex; requires fiber infrastructure<\/td>Simpler and more cost-effective to install<\/td><\/tr>
Power Requirements<\/strong><\/td>Active system; requires powered components throughout<\/td>Passive system; fewer powered components<\/td><\/tr>
Best For<\/strong><\/td>Mission-critical, large-scale public safety networks<\/td>Code-required coverage in simpler buildings<\/td><\/tr>
Compliance<\/strong><\/td>UL 2524, NFPA 1221, IFC, local AHJ requirements<\/td>UL 2524, NFPA 1221, IFC, local AHJ requirements<\/td><\/tr><\/tbody><\/table><\/figure>\n<\/div>\n\n\n\n
\n
\"\"<\/figure>\n\n\n\n
\"\"<\/figure>\n\n\n\n
\n
\n
\"\"<\/figure>\n<\/div>\n\n\n\n
\n
\n

Education, Training and Support<\/h2>\n\n\n\n

We believe that ongoing education is paramount to your professional development.<\/p>\n\n\n\n

As the code and training experts, our website offers all the documentation and educational resources needed to assist you in making the right decisions.<\/p>\n<\/div>\n\n\n\n

\n
Contact us<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"

Compare Systems at a Glance Features Fiber DAS Systems Passive DAS Systems Ideal Use Case Large buildings, high-rises, multi-building campuses Mid-sized to small buildings with straightforward layouts Signal Distribution Fiber optic cable Coaxial cable Coverage Range Long-distance signal transmission with minimal loss Shorter distances; more dependent on building layout Scalability Highly scalable across multiple floors […]<\/p>\n","protected":false},"featured_media":10534,"parent":10456,"menu_order":0,"template":"","meta":{"_eb_attr":"","inline_featured_image":false,"doo-cf-term":287,"doo-cf-codes":null,"footnotes":""},"brand":[38],"class_list":["post-9842","division","type-division","status-publish","has-post-thumbnail","hentry","brand-rath"],"_links":{"self":[{"href":"https:\/\/www.avire-global.com\/en-us\/wp-json\/wp\/v2\/division\/9842","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.avire-global.com\/en-us\/wp-json\/wp\/v2\/division"}],"about":[{"href":"https:\/\/www.avire-global.com\/en-us\/wp-json\/wp\/v2\/types\/division"}],"version-history":[{"count":5,"href":"https:\/\/www.avire-global.com\/en-us\/wp-json\/wp\/v2\/division\/9842\/revisions"}],"predecessor-version":[{"id":12968,"href":"https:\/\/www.avire-global.com\/en-us\/wp-json\/wp\/v2\/division\/9842\/revisions\/12968"}],"up":[{"embeddable":true,"href":"https:\/\/www.avire-global.com\/en-us\/wp-json\/wp\/v2\/division\/10456"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.avire-global.com\/en-us\/wp-json\/wp\/v2\/media\/10534"}],"wp:attachment":[{"href":"https:\/\/www.avire-global.com\/en-us\/wp-json\/wp\/v2\/media?parent=9842"}],"wp:term":[{"taxonomy":"brand","embeddable":true,"href":"https:\/\/www.avire-global.com\/en-us\/wp-json\/wp\/v2\/brand?post=9842"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}